Please use this identifier to cite or link to this item:
https://repositorio.ufu.br/handle/123456789/17530
Document type: | Tese |
Access type: | Acesso Aberto |
Title: | Desenvolvimento de procedimentos de digestão de biodiesel assistidos por radiação ultrassônica visando à determinação de metais por técnicas eletroquímicas |
Author: | Freitas, Helieder Cortes |
First Advisor: | Munoz, Rodrigo Alejandro Abarza |
First member of the Committee: | Veiga, Márcia Andreia Mesquita Silva da |
Second member of the Committee: | Trovó, Alam Gustavo |
Third member of the Committee: | Augelli, Marcio Antonio |
Fourth member of the Committee: | Silva, Sidnei Gonçalves da |
Summary: | Esta tese apresenta o emprego da radiação ultrassônica para a digestão de amostras de biodiesel (B100) para a determinação dos íons metálicos por técnicas eletroquímicas de redissolução (potenciomérica e voltamétrica) empregando eletrodo de carbono vítreo modificado com filme de mercúrio. Amostras de biodiesel (50 mg) foram submetidas a digestão em tubos de vidro, com uma mistura de 3,0 mL de HCl concentrado e 4,4 ml de H2O2 (30%), colocados em um banho ultrassônico (40 kHz e 120 W) exatamente sobre a região de intensidade mais elevada (piezoelétricos) do ultrassom e sonicada durante 40 min a temperatura ambiente (~ 20 ºC). Estes parâmetros foram otimizados empregando-se a técnica quimiométrica de planejamento fatorial para a análise de amostras de biodiesel enriquecidas com soluções padrão etanólicas de zinco, cádmio, chumbo e cobre. Valores de recuperação entre 97 e 107 % foram verificados na condição de ótimo encontrada para zinco, cádmio, chumbo e cobre. Valores de RCC (teor de carbono residual) nos digeridos encontraram-se na faixa de 3,05-3,75%. A determinação simultânea de zinco, cádmio, chumbo e cobre empregando voltametria de redissolução anódica revelou valores de limite de detecção (LD) de 44 ng Kg-1; 30 ng Kg-1; 145 ng Kg-1 e 96 ng Kg-1, respectivamente. Adicionalmente, amostras de biodiesel (100 mg) também foram tratadas em tubos de vidro com uma mistura de 1,59 mL de HCl concentrado e 3,0 ml de H2O2 (30%), sob sonicação de uma sonda ultrassônica (tempo de sonicação de 12,5 minutos, amplitude de 25 %, tempo de pulso de 5,0 s em intervalo 2,0 s). Os parâmetros também foram otimizados empregando-se técnica quimiométrica de planejamento fatorial para a análise de amostras enriquecidas. Valores de recuperação entre 95 e 104% foram verificados nas condições satisfatórias para os íons metálicos zinco, cádmio, chumbo e cobre. Valores de RCC após as digestões compreendem valores entre 0,43-0,54 %. Na determinação simultânea de zinco, cádmio, chumbo e cobre empregando voltametria de redissolução anódica nos digeridos obtidos após tratamento com a sonda ultrassônica, os valores de LD encontrados respectivamente para os íons metálicos zinco, cádmio e cobre foram de 25 ng Kg-1 e para íon chumbo de 56 ng Kg-1. Todos os resultados obtidos empregando digestão assistida por banho de ultrassom e /ou sonda de ultrasssom indicam que os métodos propostos para o preparo de amostra de biodiesel apresentam um desempenho comparável aos metodos tradicionais de digestão que utilizam misturas ácidas, ou ainda as digestões assistidas por radiações de microondas. |
Abstract: | This thesis presents the use of ultrasonic radiation for the digestion of biodiesel samples (B100) for the determination of metal ions by electrochemical stripping techniques (potentiometric and voltammetric) using a glassy-carbon electrode modified with a mercury film. Biodiesel samples (50 mg) were subjected to digestion in glass tubes with a mixture of 3.0 mL of concentrated HCl and 4.4 ml H2O2 (30%), placed in an ultrasonic bath (40 kHz and 120 W) exactly on the higher intensity region (piezoelectric) of the ultrasound and sonicated for 40 min at room temperature (~ 20°C). These parameters were optimized using the chemometric technique of factorial design for the analysis of biodiesel samples spiked with ethanolic standard solutions of zinc, cadmium, lead and copper. Recovery values between 97 and 107% were observed in the optimal conditions found to zinc, cadmium, lead and copper. Residual carbon content (RCC) values after digestions were in the range of 3.05 to 3.75%. The simultaneous determination of zinc, cadmium, lead and copper using anodic stripping voltammetry revealed limit of detection (LD) values of 44 ng kg -1; 30 ng kg -1; 145 ng kg -1; 96 ng kg -1, respectively. Additionally, biodiesel samples (100 mg) were also treated in glass tubes with a mixture of 1.59 mL concentrated HCl and 3.0 ml H2O2 (30%) under sonication of an ultrasonic probe (sonication time 12.5 min, 25% amplitude, pulse of 5.0 s and time interval of 2.0 s). The parameters were also optimized employing the chemometric technique of factorial design for the analysis of spiked samples. Recovery values between 95 and 104% were observed in the satisfactory condition for zinc, cadmium, lead and copper. RCC values after digestions comprised values between 0.43 to 0.54%. For the simultaneous determination of zinc, cadmium, lead and copper using anodic stripping voltammetry obtained in the digestates employing the ultrasonic probe, the LD values found respectively for zinc, cadmium and copper were 25 ng kg -1 and for lead 56 ng kg -1. All results obtained using assisted digestion by ultrasonic bath and / or ultrasonic probe indicate that the proposed methods for the biodiesel sample preparation presents a comparable performance to traditional methods of digestion using acid blends, or yet digestions assisted by microwave radiation. |
Keywords: | Biodiesel Ultrassom Sonicação Preparo de amostra Eletroanálise Metais Ultrasound Sonication Sample preparation Electroanalysis Metals Análise eletroquímica |
Area (s) of CNPq: | CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA |
Language: | por |
Country: | BR |
Publisher: | Universidade Federal de Uberlândia |
Institution Acronym: | UFU |
Department: | Ciências Exatas e da Terra |
Program: | Programa de Pós-graduação Multi-Institucional em Quimica (UFG - UFMS - UFU) |
Quote: | FREITAS, Helieder Cortes. Desenvolvimento de procedimentos de digestão de biodiesel assistidos por radiação ultrassônica visando à determinação de metais por técnicas eletroquímicas. 2015. 153 f. Tese (Doutorado em Ciências Exatas e da Terra) - Universidade Federal de Uberlândia, Uberlândia, 2015. DOI https://doi.org/10.14393/ufu.te.2015.160 |
Document identifier: | https://doi.org/10.14393/ufu.te.2015.160 |
URI: | https://repositorio.ufu.br/handle/123456789/17530 |
Date of defense: | 16-Dec-2015 |
Appears in Collections: | TESE - Química (Multi-Institucional UFG - UFMS - UFU) |