Publicação:
Evaluation of efficiency of different imaging methods and softwares to analyse radiopacity of conventional bulk fill composite resins

dc.contributor.advisor-co1Barcelos, Luciana Mendes
dc.contributor.advisor-co1Latteshttp://lattes.cnpq.br/5425527112984849pt_BR
dc.contributor.advisor1Soares, Carlos José
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/3485765805045929pt_BR
dc.contributor.referee1Moura, Camilla Christian Gomes
dc.contributor.referee2Soares, Priscilla Barbosa Ferreira
dc.creatorGoulart, João Vítor
dc.creator.Latteshttp://lattes.cnpq.br/6875347940193729pt_BR
dc.date.accessioned2019-06-28T23:40:27Z
dc.date.available2019-06-28T23:40:27Z
dc.date.issued2019-06-26
dc.description.degreenameTrabalho de Conclusão de Curso (Graduação)pt_BR
dc.description.resumoAIM: This study aimed to present a laboratory device used for obtain standardized X-ray images and used for analysis of resin composites using two radiographic methods and two imaging process data. METHODS AND MATERIALS: The device with lead protection and glass visor that stabilize the x-ray tube and permitted the stabilization of the samples and different x-Ray films and sensors was created. Specimens with 5.0mm in diameter and 2.0mm in thickness of 2 nanohybrid (Filtek Z350, 3M-ESPE and Vittra APS, FGM) and 4 bulk fill composites (Filtek Bulk fill Posterior, 3M-ESPE, Opus Bulk Fill Regular (FGM), Opus Bulk fill flow (FGM), and Tetric Evoceram Bulk fill (Ivoclar Vivadent) were tested. The x-ray images were obtained positioning one sample for each resin composite and aluminium step wedge over two sensors: direct digital sensor (Acteon) and Phosphor Plate (VistaScan, Dürr Dental). Images were analysed using two software’s (Image J and DBSWIN, Dürr Dental) to calculate the radiopacity level comparing resin composites and also with the aluminium step wedge. Data were analysed by three-way ANOVA followed by Tukey test (=0.05). RESULTS: The developed devise was efficient to protect secondary radiation and to standardize the x-ray images. All resin composite showed recommended radiopacity level irrespective of the radiographic method or software analysis. CONCLUSION: Bulk fill and conventional composite resins exhibit variability in radiopacity, with values considered above the dentin values. Radiographic methods and software tested showed similarity ranking capacity for radiopacity of the composite resins, changing only the calculated values. The device was able to standardize the different radiographic methods used in this in vitro study to assess radiopacity of restorative materials.pt_BR
dc.description.sponsorshipCNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológicopt_BR
dc.identifier.citationGOULART, João Vítor. Evaluation of efficiency of different imaging methods and softwares to analyse radiopacity of conventional bulk fill composite resins. 2019. 17 f. Trabalho de Conclusão de Curso (Graduação em Odontologia) – Universidade Federal de Uberlândia, Uberlândia, 2019.pt_BR
dc.identifier.urihttps://repositorio.ufu.br/handle/123456789/25555
dc.languageengpt_BR
dc.orcid.putcode58961737
dc.publisherUniversidade Federal de Uberlândiapt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.courseOdontologiapt_BR
dc.rightsAcesso Abertopt_BR
dc.sizeorduration17pt_BR
dc.subjectDigital X-raypt_BR
dc.subjectRadiopacitypt_BR
dc.subjectBulk fill composite resinpt_BR
dc.subject.cnpqCNPQ::CIENCIAS DA SAUDE::ODONTOLOGIApt_BR
dc.titleEvaluation of efficiency of different imaging methods and softwares to analyse radiopacity of conventional bulk fill composite resinspt_BR
dc.typeTrabalho de Conclusão de Cursopt_BR
dspace.entity.typePublication

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
EvaluationEfficiencyDdifferent.pdf
Tamanho:
1.72 MB
Formato:
Adobe Portable Document Format
Descrição:

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.75 KB
Formato:
Item-specific license agreed upon to submission
Descrição: